Skip to main content

Table 2 Receiver operating characteristic analysis of DcR3, suPAR and PCT in control and SIRS

From: Diagnostic value of decoy receptor 3 combined with procalcitonin and soluble urokinase-type plasminogen activator receptor for sepsis

 

AUC

SID error

Sig

95%CI

Cut-off value

Sensitivity

Specificity

Lower limit

Upper limit

DcR3

0.768

0.063

0.001

0.643

0.892

0.190 ng/mL

0.79.4

0.550

suPAR

0.876

0.048

0.000

0.781

0.970

0.519 ng/mL

0.85.3

0.850

PCT

0.858

0.051

0.000

0.758

0.958

0.375 ng/mL

0.824

0.800

DcR3 + suPAR

0.893

0.044

0.000

0.807

0.978

0.440

0.853

0.850

DcR3 + PCT

0.875

0.047

0.000

0.783

0.967

0.517

0.794

0.850

suPAR+PCT

0.946

0.029

0.000

0.890

1.000

0.308

0.971

0.800

DcR3 + suPAR+PCT

0.947

0.028

0.000

0.893

1.000

0.310

0.941

0.800