Skip to main content

Table 3 Receiver operating characteristic analysis of DcR3, suPAR and PCT in control and sepsis

From: Diagnostic value of decoy receptor 3 combined with procalcitonin and soluble urokinase-type plasminogen activator receptor for sepsis

 

AUC

SID error

Sig

95%CI

Cut-off value

Sensitivity

Specificity

Lower limit

Upper limit

DcR3

0.990

0.009

0.000

0.971

1.000

0.545 ng/mL

0.971

0.900

suPAR

0.938

0.040

0.000

0.859

1.000

5.535 ng/mL

0.941

0.850

PCT

0.972

0.019

0.000

0.935

1.000

0.513 ng/mL

0.941

0.870

DcR3 + suPAR

0.996

0.005

0.000

0.986

1.000

0.489

0.971

0.950

DcR3 + PCT

0.990

0.011

0.000

0.968

1.000

0.237

0.971

0.950

suPAR + PCT

0.969

0.028

0.000

0.915

1.000

0.297

0.971

0.900

DcR3 + suPAR + PCT

0.997

0.004

0.000

0.989

1.000

0.345

0.971

0.980